 1 - Version Information
=====================================

Product:       SmartPlant License Manager (SPLM)
Number:        SEBY281AV-1200A
Version:       2012 (12.00.05.00)
Date:          21-Mar-2012
	
Description:   PPM Licensing Product

-------------------------------------
 ///////// End of Version Information
-------------------------------------

=====================================
 2 - System Requirements
=====================================

SPLM does not support any type of virtualization on the license machine (the 
machine where you install the SPLM key.) 

The SPLM license machine is sensitive to dynamic hardware configurations because 
of security measures within the SPLM software. 

Define a SPLM license machine that can best provide uninterrupted license 
management for Intergraph applications.

The SPLM license machine should be a stable, single node, hardware configuration 
(such as a simple PC), with a static IP address. The license key installation 
and license seat usage authentication depends on the information gathered from 
the physical hardware.

Any automated, intentional or unintentional changes that cause the hardware 
information not to match with the information used to generate the license key 
will result in a failure of the authentication process. Virtual, shadowed, 
mirrored, dynamic, or distributed hardware configurations will not work as the 
SPLM license machine. This can include terminal (application) servers, networked 
and distributed storage management systems, etc. When these specialized systems 
occur in the users' network.

The SPLM license system should be situated on the users'network where it can be 
accessed by all systems that are running application software that relies on 
the SPLM license machine for license management. Multiple SPLM license machines 
can be used in the users' network as long as each system is a unique 
system/installation.

If SLPM license machines are used to clone other hardware systems after the 
license key has been installed then the license management will fail on the 
cloned system. Each SPLM license system/installation requires its own unique 
license key.

-------------------------------------
 ///////// End of System Requirements
-------------------------------------

=====================================
 3 - Version Compatibility
=====================================

For up-to-date information on the software compatibility of this product in a 
standalone or integrated environment, please refer to the Compatibility Matrix
on the Intergraph PPM Support Web site at http://crmweb.intergraph.com/.

Log on and perform the following steps:

1. Click the Service tab. 
2. Click the Download Software Updates link. 
3. On the Table of Contents page, click Products. 
4. On the Product page under Compatibility Matrices (Now in Database Format), click the 'PPM Compatibility Matrices Database' link.  
5. On the PPM Compatibility Matrix - Product Report page, from the Select the Product Code list, select SPLM. 
6. From the Select the version list, select the desired version of SPLM.
For information about authoring tool versions that work with a particular version of SmartPlant Foundation, follow the same steps listed above except select SPEnterprise in step 5. 
 
-------------------------------------
 ///////// End of Version Compatibility
-------------------------------------

=====================================
 4 - Special Instructions
=====================================

----------------
Installing SPLM
----------------
The license software is delivered on SPLM media. You can also
download it from the Intergraph PPM Support Web site at
http://crmweb.intergraph.com

Log in and select the following options:

- "Download Software Updates"
- "Products"
- "SPLM"

The SmartPlant License Manager Installation and User's Guide DPDS3-PB-200019G
Version 2012 (12.0) June, 2012 is located at:

- "Download Software Updates"
- "Product Documenation"
- "SmartPlant License Manager"

To install this product, double-click on the setup.exe file.  This activates 
the install shield that allows you to select the installation options.

---------------
Upgrading SPLM
---------------

- For SPLM License Machine:

  - If you currently have SPLM v11.00.17.00 installed on your license machine, you can upgrade to
    SPLM 2012 v12 directly, but you must generate a new machine ID and request a new key after the upgrade. 

  - If you currently have SPLM 2008 v10 or previous version installed on your license machine, you must
    uninstall existing SPLM version prior to installing SPLM 2012 v12. You must generate a SPLM v12
    machine ID and request a v12 license key after you installed SPLM v12.00.05.00 on the license machine. 

  - To minimize downtime during the upgrade or uninstall/reinstall process on your SPLM License Machine, you can 
    pre-request a SPLM 2012 v12 license key for your SPLM v11 or v10 or v9 License Machine. Please refer to 
    "Important Upgrade Info for SPLM 2012" on eCustomer and eLicense sites for details. 

  - SPLM 2012 v12 License Machine supports all previous versions of SPLM on Client Machines.


- For SPLM Client Machine:

  - If you currently have SPLM v11.00.17.00 installed on your Client machine, you can upgrade to
    SPLM v12 directly. No need to uninstall / reinstall SPLM.  

  - If you currently have SPLM 2008 v10 or previous SPLM version installed on your Client machine, you must
    uninstall existing SPLM version prior to installing SPLM 2012 v12. 

  - SPLM Client machine cannot have a newer version of SPLM than is installed on the SPLM license machine. 


Note: 
A special upgrade document is available with additional information how to minimize
downtime during the upgrade process. The document "Important Upgrade Info for 
SPLM 2012" is available on eCustomer and eLicense sites.

-------------
Helpful Hints
-------------
  
 - Getting Started
   ------------------------------------------------
   To use the SPLM license manager software it is necessary to contact Intergraph 
   to obtain a license key. The license key will correspond to the number of 
   licenses purchased.  It will be necessary to furnish the Machine Identifier file 
   (generated using SmartPlant License Manager), the number of licenses requested 
   and the date the key will be installed.  Please refer to License Key Request 
   Forms in the SmartPlant License Manager Installation and User's Guide 
   (DPDS3-PB-200019*) for the required forms.

 - Generate Machine ID
   ------------------------------------------------
   Machine ID is required from license machine to request a license key. 

   If SPLM 2012 v12 is installed on your license machine, you can run "Generate 
   Machine ID" from the Start > Programs > Intergraph SmartPlant License 
   Manager > Generate Machine ID.  Select the Browse button and define the path 
   and filename for the Machine ID output file.

   If a previous version of SPLM is installed on the license machine and you 
   need to request a v12 license key in advance to prevent production down time, 
   you need to download the Generate Machine ID 2012 executable from the 
   eCustomer web site.  Copy the SPLMGenMachineID_2012.exe to a temporary 
   location and generate a v12 machine ID.  Please refer to the "Important 
   Upgrade Info for SPLM 2012" on eCustomer SPLM site for details.

   CAUTION: 
   After you send the machine ID to us, do NOT run Generate Machine ID 
   command again until the license key is installed. Running Generate Machine 
   ID again will invalidate the existing machine ID you sent to us and cause 
   the license key you receive not to install.  

   If you generate a new Machine ID after installing the license key, the 
   license machine will continue to work.  However, you will have to supply 
   this new Machine ID to Intergraph when requesting a new or updated 
   license key. 
 
 - License Key installation
   -------------------------------------------------
   Removing the license key requires that you run generate Machine Identifier
   again and receive a new license key from Intergraph.  There is no need to 
   remove the old key because you can simply install the new key over the old 
   key. If you remove the key you will need to request a new one.
 
 - SPLM installation File Path
   ------------------------------------------------
   We recommend you install SPLM in its default location (c:\winapp32\ingr)
 
 - SPLM with Firewall
   ------------------------------------------------
   pdlice.exe must be added to the Exception List in Windows Firewall to
   allow the license machine to scavenge properly if a workstation 
   abnormally closes a product.  If it is not added to the Exception List, 
   the scavenge request will timeout for the workstation and not recover the seat.
 
 - Restore Prohibited
   ------------------------------------------------
   SPLM key files are stored on the license machine in the Windows 
   registry under:
   
   HKEY_LOCAL_MACHINE\SOFTWARE\Intergraph\Pdlice_etc

   DO NOT RESTORE this key or any of its sub-keys from a backup, as this
   invalidates the data stored in these files and requires a new key to
   be installed.

 - Select License Machine requires administrator's privilege. 
   --------------------------------------------------

 - TCP/IP Port No.
   -------------------------------------------------
   SPLM uses the TCP/IP port no. 807 to communicate with other systems
   over the network. Since port numbers are not distributed by a central
   authority on Windows, there is a very small likelihood that some other 
   program may already be using the same port number.  
   The SPLM service may fail to start on account of such a conflict.
   If the Application Event Log so identifies the problem, please disable 
   the offending program and restart SPLM.

 - SPLM Error Messages 
   -------------------------------------------------
   Please consult the Windows Application event log for possible
   SPLM Error Messages.  SPLM writes to the event log if there is no
   other avenue for presenting error messages - particularly for
   unattended service related failures. Also check the Troubleshooting
   section on the documentation and the product log and scavenge file.

 - SPLM product removal
   -------------------------------------------------
   To remove SPLM use Add/Remove Programs from Control Panel. After 
   removing the product, user will need to generate a new Machine Identifier 
   and request a new key for the license machine.

-----------
Limitations
-----------
 
 -  SPLM does not support any RAID or SAN configuration on License Machine. 

 - It is required to have a static TCP IP address on the license machine. If  
   that is not possible we suggest to create a virtual network connection
   by installing Microsoft Loopback Adapter. 

 - The SmartPlant License Manager licensing machine is not fully functional 
   when communicating across any network device that obscures the client's IP 
   address.  This includes but is not limited to NAT routers or VPN solutions. 

 - SPLM 2012 v12 license usage log file will not contain the domain name for 
   PDS products.

 - SPLM doesn't support client and machines working behind a firewall application.
   
 - In a networked configuration where users workstations are accessing one or
   more engineering application servers the SPLM machine should be installed on
   a separate node, not on the application server. SPLM machine is not tested, 
   certified or supported when configured on an Application Server running Windows
   Terminal Server and/or products such as Citrix Server.

 - Virus scan software is not supported on the license machine.

 - SPLM does not support NT.

 - SPLM license machine doesn't support multiple network devices such as NIC 
   team on a single system.  

 - SPLM does not support the license machine to be inside a VM session. It is 
   supporting SPLM client inside a VM session.

 - EMBASSY Trust Suite by Wave Systems is not supported on the license machine. 
   One would get [Reading Socket] Connection reset by peer message when 
   reserving license. This software is often found on many of different Dell 
   laptops. One needs to remove this software on the license machine. 

 - SPLM does not support Acceleration client in AT&T or Cingular Communication 
   Manager on license machine. One would get [Reading Socket] Connection 
   reset by peer message when reserving seat. One needs to uninstall
   Acceleration client in AT&T or Cingular Communication Manager (Tools > 
   Settings > Acceleration tab > Client: Uninstall) and reboot the license 
   machine. 

 - If you are working in a heterogeneous environment, you need to use the 
   license machine's IP address instead of the actual name (node name).


-------------------------------------
 //////// End of Special Instructions
-------------------------------------

=====================================
 5 - Documentation
=====================================

Use the Help menu to access the Help files and Printable Guides for this product.  To suggest a change or to ask a question about the documentation, send an e-mail message to PPMdoc@intergraph.com

Printed documentation is not available for separate purchase.

PDF File Reader
The documentation is provided as .pdf files. To view the .pdf files, you must install a PDF file reader.


-------------------------------------
 //////// End of Documentation
-------------------------------------

=====================================
 6 - Training
=====================================

Currently no training is available for this product.

For current information on Intergraph training in general, use a World Wide Web 
browser to connect to http://www.intergraph.com/training/.
-------------------------------------
 /////////            End of Training
-------------------------------------

=====================================
 7 - Customer Support
=====================================

For the latest Support Services information for this product, including solutions to known software issues, use a World Wide Web browser to connect to http://support.intergraph.com/.


To open service requests outside the U.S., please contact your local Intergraph office.

-------------------------------------
 /////////    End of Customer Support
-------------------------------------

=====================================
 8 - New Features
=====================================

 - CR  70851 
	A new counted type seat for the license key is now available for use by some products.

 - CR  73949
	The Status window of the SPLM gui is now resizable.

 - CR 105019
	The SPLM GUI tag list for Test Reserve Seat command now displays the tag list from the license key of the selected license machine.

 - CR 105272
	After upgrading the license machine software from v11 to v12, the License Machine options in the GUI are available for use.

 - CR 105385
	Disabled the pdlice -Q and pdlice -N commands on the client machine.
  
 - CR 106107
	Disabled the pdlice -c command on the client machine.

 - CR 106119
	Disabled the pdlice -L command on the client machine.

 - CR 107631
	Added Chinese SLA to SPLM setup.
  
 - CR 107667
	Added GUI options for Test Seat Reservation and Test Seat Release using the Current User registry settings to obtain the list of license machines.

 - CR 108219
	Stopped GUI from closing the "Install License Key" window when an invalid key is entered.
  
 - CR 109830
	Added SPLM version to the machine id output file.

 - CR 109850
	Added GUI options to allow the creation of the registry settings under Current User for Select License Machine and Remove License Machine commands.
  
 - CR 109929
	Removed requirement that pdlice_etc had to be exported if you were upgrading the license machine and had already obtained a new license key for the new version of SPLM.

 - CR 112291
	During installation the Log Product Usage setting is activated and the log file name is defined.  The log file name is located in the SPLM \bin directory and is named loggingfileV12.txt.  
	WARNING:  The log file could grow very large.
  
 - CR 112292
	During installation the Scavenge output file name is defined.  The scavenge file name is located in the SPLM\bin directory and is named scavengeV12.txt.

 - CR 113587
	The journal file for SPLM 2012 (v12) is now named SPLMv12journal.  The journal files will retain the v12 in their name when they are moved to the archive folder by SPLM.
  
 - CR 114468
	Added Intergraph logo to the GUI.
  
 - CR 118741
	On the license machine added the ability for the user to define the number of days to display the expiring license key message.  The default is 45 days.
 
 - CR 123163
	On the license machine added the ability for the user to define the minimum number of counted seats remaining on a tag in the license key before displaying a warning message.  The default is 100 counted seats.
  
 - CR 124698
	When you run setup for SPLM 2012 (v12) and SPLM 2010 (v11) is currently installed on your machine, setup will display an upgrade message.

 - CR 127456
	When you run setup for SPLM 2012 (v12) and SPLM 2010 (v11) license machine is currently installed on your machine, setup will display a warning message that the existing license key will become invalid when you upgrade.

 - CR 127603
	Enhanced Audit Code to include information on new counted seats.   


-------------------------------------
 /////////        End of New Features
-------------------------------------

=====================================
 9 - Fixes
=====================================
 
 - TR 106992
	Before installing a key, the client would get "License Key has Expired" message from the license machine.
 
 - TR 108765
	When running the Repair option, the SPLM service was not stopped and restarted correctly.
 
 - TR 108984
	If you enter the license machine with a space at the end, the SPLM gui will crash when using the "Select License Machine for Client" command.
  
 - TR 111113
	In options to display the Key, i.e, Show Key Status or Status of Reserved License, the SPPD tag includes an extra character.

 - TR 113815
	Changed error message in pdlice -l (display license machine) when there are no license machines defined.

 - TR 114996
	The GUI options changed on license machine in same open session after generating machine identifier.
  
 - TR 115407
	In the GUI Install Key command When the key contained tags for all tags, the key was not displayed correctly in the field.
  
 - TR 116195
	Intergraph was misspelled in the Help About dialogue box.
  
 - TR 120421
	The content on SPLM Help About should be read only.

 - TR 124986
	In the GUI Test Seat Reservation command, the SPPD tag included a garbage character in the tag list.
  
 - TR 124990
	Added new pdlice commands pdlice -Z and pdlice -r n in pdlice -? and pdlice -h.

 - TR 125373
	Corrected problems when installing key after IP was modified.


-------------------------------------
 /////////               End of Fixes
-------------------------------------

=====================================
 10 - Open Problems
=====================================

 - TR 72999  "Connection Reset by Peer" message when reserving a license seat 
   caused by Panda Antivirus on the license machine only.  This can be caused by 
   other virus scan software too. 
   Workaround: Uninstall virus scan software on your license machine.


 - TR 77218 - SPLM fails to return the seat when the client machine changes 
   IP addresses between the get seat request and the return seat request.
   Workaround:  Scavenge will release the seat immediately if it can communicate 
   with the client or after 16 hours if it cannot communicate with the client.

 - TR 106102  Strange characters are reported in the usage log file for node 
   name for SPRD and SPMAT products. 
   Note: This is pending fix from SmartPlant Materials and SmartPlant Reference Data.

 - TR 106104  Usage log file has SYSTEM reported as the UserName for SPRD product.  
   Note: This is pending fix from SmartPlant Materials and SmartPlant Reference Data.

 - TR 108316  The usage log file incorrectly reports the UserName when using 
   Citrix server or Remote Desktop Services.
   Note: To implement this fix, product applications must be rebuilt with SPLM 20102 v12.  

 - SmartPlant Instrumentation TR  72957
   If SPLM client has multiple license machines in the license machine list and 
   the first license machine does not have an SPI license/option word defined, SPI 
   will not start.     
   Workaround: Make sure that the license machine that has SPI license/option 
   word is the first one in the license machine list. 

-------------------------------------
 /////////       End of Open Problems 
-------------------------------------
  
=====================================
 11 - Legal Notices
=====================================

Copyright (c) 1991-2012 Intergraph Corporation
All Rights Reserved

Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement; contains confidential and proprietary information of Intergraph and/or third parties which is protected by copyright and trade secret law and may not be provided or otherwise made available without proper authorization.

RESTRICTED RIGHTS LEGENDS

Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of The Rights in Data and Computer Software clause at DFARS 252.227-7013 or subparagraphs (c) (1) and (2) of Commercial Computer Software-Restricted Rights at 48 CFR 52.227-19, as applicable.

Intergraph and the Intergraph logo are registered trademarks of Intergraph Corporation in the United States and in other countries.  The following are trademarks and service marks owned by Intergraph Corporation or its subsidiaries worldwide: http://www.intergraph.com/terms/trademarks.asp

Unpublished--rights reserved under the copyright laws of the United States.
Intergraph Corporation
Huntsville, Alabama 35894-0001

-------------------------------------
 /////////       End of Legal Notices 
-------------------------------------